Vertrod Style Steel Frame Pivot
Heat Sealer
|
| Recommended for, but not limited to, Heavy
Duty and/or High Volume usage. Jaw opening options
available up to 12" or more for easy sealing of bulky
packages such as blankets, comforters or towels. Heater
bar placement options available: heater bar on top
allows for trouble-free sealing of Tyvek pouches;
double-sided heat for sealing of thick materials up to
80MIL (.80") or for sealing high temperature materials
such as Teflon, Tedlar, etc. Custom mounting options
available to allow sealer to operate at any angle, 0-360
degrees. Compression device can be added to reduce
package thickness for more efficient shipping and/or
storage. |
|
- Seal Lengths Available: 14", 20", 24", 30",
36", 48", 60", 72", 84", 96", 108" & 120"
(custom lengths & configurations available
upon request).
- Seal Widths Available: 1/8", 3/16", 1/4", 3/8"
& 1/2" (custom widths & configurations
available upon request).
- Water-Cooled or non Water-Cooled Heater
Bar.
- Heater Bar & Pressure Bar equipped with our
easy-to-replace Teflon.
- Hammertone Grey or FDA Compliant
White powder coated finish.
- All Stainless Steel Fasteners.
- Maintenance-Free Greaseless Needle
Bearings.
- Trim Seal option available.
- PLC Time Control* or Temperature Control**
System.
- User Programmable Heat Time & Cool
Time*/Low Temp & High Temp** set points.
- Measures Temperature in the actual process
area on Heater Bar(s)**
- Operator Burn Protection - Ensures that the
heated parts of the machine are not accessible to the
operator until the low temperature set point is
reached.**
- Ensures that the melt temperature of the
material is reached on every cycle (accurate to
within approx. 5 Degrees Fahrenheit).**
|
- User-adjustable Software Rheostat allows
the operator to program the rate of temperature rise.
- Runaway Heat Protection (shuts down all
system controls if the temperature exceeds the
setpoint by 100 Degrees Fahrenheit).
- 24VDC Control Circuitry.
- 2-Line x 20-Character Operator Interface.
- Text Error Messaging.
- Numeric Keypad Input.
- LED Indicator Lights.
- 50mm Emergency Stop.
- Cycle Counter (up to 99999-resetable).
- Cycle Timer (displays Cycle Time in tenths
of a second).
- Operates on Main Power Output of 120VAC 50/60Hz
(220VAC available).
- Voltage Control (maintains constant output
to the heater element during low/high voltage
episodes.
- Proximity Switch Sensing.
- Obstruction Detection (opens sealing jaws
before going to high pressure if obstruction is
detected).
- Pressure Sensor - ensures that income line
pressure is adequate before allowing the operator to
begin the sealing process(optional add-on).
- Pneumatic Air Cylinder.
- Footswitch
Activated.
|
* Time Control Systems only. **
Temperature Control Systems
only.
|
Ordering Instructions: Your part number
will consist of a Model Number (seal length) and seal
width e.g. part# 36SF-1/4 indicates a 36" Seal
Length and 1/4" Seal Width.
Compile your part
number from the table below: |
|
14SF |
14" Seal Length |
1/8 |
1/8" Seal Width |
|
20SF |
20" Seal Length |
3/16 |
3/16" Seal Width |
|
24SF |
24" Seal Length |
1/4 |
1/4" Seal Width |
|
30SF |
30" Seal Length |
3/8 |
3/8" Seal Width |
|
36SF |
36" Seal Length |
1/2 |
1/2" Seal Width |
|
48SF |
48" Seal Length |
|
|
|
60SF |
60" Seal Length |
|
|
|
72SF |
72" Seal Length |
|
|
|
84SF |
84" Seal Length |
|
|
|
96SF |
96" Seal Length |
|
|
|
108SF |
108" Seal Length |
|
|
|
120SF |
120" Seal Length |
|
| | All
other configurations, please call, fax or email our Sales
Department.
|
|