          Controller Features

  • Operates on incoming main power of 85 to 240vAC, 50/60 Hz.
  • Uses 24VDC control circuits for operator safety.
  • Voltage Drop Control - maintains constant wattage to heater element during low voltage episodes.
  • Obstruction Detection - Accurate to within 2mm to ensure the safety of your operators near critical pinch points.
  • Advanced Temperature Control System - Temperatures in the sealing area can be controlled to plus or minus 5 degrees Fahrenheit.
  • Runaway Heat Protection - Shuts down all system controls in the event of runaway heat.
  • Operator Burn Protection - Ensures that heated parts of the machine are not accessible to the operator until a safe temperature is reached.
  • Resetable Cycle Counter (pass code protection optional)
  • Low/High Temp Set-Points (pass code protection optional)
  • Modem Communication - Ability to communicate with your Impulse Heat Sealer via phone modem for remote diagnosis of problems that may occur and to add new features to our Heat Sealer as they become available.
  • Improved Cycle Times.
  • Data Acquisition - Our QA Assistant package (sample below) allows user to log all system parameters of each cycle into an Excel spreadsheet. Our proprietary system of data acquisition and retention starts with the eight basic data points essential to the validation process - DATE & TIME STAMP; CYCLE COUNTER; LOW TEMP SETTING; HIGH TEMP SETTING; MAX TEMP REACHED; CYCLE TIME, AIR LINE PRESSURE & ERROR CODES. Note the tight close range of temperature reached at the MAX point (actual seal temperature) and Cycle time. Such consistency results in the highest quality and reliability in the sealing process for your packaging requirements

  
 
 
 Date & Time  Cycle Counter  Low Temp Setting  High Temp Setting  Highest Temp Reached  Cycle Time  Air Line Pressure  Error Code
 10/18/01 9:11 70 150 300 303 3.3 65 0
 10/18/01 9:12 71 150 300 305 3.3 65 0
10/18/01 9.39 72 150 300 304 3.3 65 0
10/18/01 9.41 73 150 300 303 3.3 65 0
10/18/01 9:43 74 150 300 303 3.3 65 0
10/18/01 9:44 75 150 300 305 3.3 65 0
 10/18/01 9:45 76 150 300 307 3.3 65 0
10/18/01 9:46 77 150 300 306 3.3 65 0
10/18/01 9:49 78 150 300 306 3.3 65 0
1018/01 9:50 79 150 300 306 3.3 65 0
10/18/01 9:51 80 150 300 305 3.3 65 0
10/18/01 9:52 81 150 200 204 1.9 65 0
10/18/01 9:53 82 150 200 205 1.9 65 0
10/18/01 9:54 83 150 200 206 1.9 65 0
10/18/01 9:55 84 150 200 205 1.9 65 0
10/18/01 9:56 85 150 200 205 1.9 65 0
10/18/01 9:57 86 150 200 205 1.9 65 0
10/18/01 9:58 87 150 200 205 1.9 65 0
10/18/01 9:59 88 150 200 205 1.9 65 0

  *Actual data extract


 